<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-12 05-55-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 33 dBuV R-PCE
Pilot RDS Phase Difference
6.6 kHz 3.9 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
16 kHz 42 kHz 14967 0,0668
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,8 dBr -0,89 dBr -0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 5:55, 12.01.2024
RT
"BEATLES - HERE COMES THE SUN "
AF EON
98.6, 101.0, 102.4, 104.7 MHz -
FM Scope Max at: 42 kHz MIN: 16 kHz % above 77 kHz: 0,0668 Acquired: 2024/01/12 5:55:22 Total samples: 14967 Equivalent time: 0:12:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,6 dBr MIN: -1,8 dBr AVE: -0,89 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2024/01/12 5:55:22) 05:42 05:44 05:46 05:48 05:50 05:52 05:54 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality